Canopy Air Production Systems (CAPS)
Provides essential weather protection while allowing for natural ventilation in warm climates. Delivers simplified installation, open access to equipment, and power upon delivery.
With a self-contained footprint, the CAPS build is easily expandable and fully mobile. It offers fast installation, cost-effective and dependable air, and allows you to be ready for production immediately upon delivery. Configurable for single, dual and triple compressor builds.

Standard: Insulation Range (°F): 36 — 120
Low Ambient: Insulation Range (°F): 10 — 120
01
Engineered for Environment
Each CAPS system is engineered for warm-climate operation, integrating compressors, air treatment, and controls into an open-air canopy design. Built to perform reliably without full enclosure, while maintaining efficiency and long-term adaptability.
02
Delivered Ready to Run
Every unit arrives fully assembled, wired, piped, and tested—requiring only power and a header connection. This streamlined approach reduces installation time, minimizes site disruption, and enables fast, predictable startup.
03
Flexible & Scalable
CAPS systems are designed to scale with demand. Modular configurations allow capacity to be added without reworking existing infrastructure, supporting both immediate production needs and future expansion.

SPECS & CUSTOMIZATIONS
Precision Engineering,
Expert Craftsmanship
Built by our in-house engineering and manufacturing teams within a 52,000 sq ft facility. Fabricated and tested under one roof to deliver consistent performance and streamlined installation.


Open-Air Canopy Design
Provides weather protection while allowing continuous natural airflow in warm environments.
Integrated System Layout
Compressors, air treatment, and controls arranged for efficient operation and simplified installation.
Rapid Deployment
Delivered assembled and tested for quick connection to power and air.
Service Accessibility
Open layout allows easy access for maintenance, inspection, and long-term reliability.

15-unlimited
Available Horsepower Range
10-120
Insulation Range (°F)
200-800
Enclosure Footpring
(sq. ft.)
SPECS & CUSTOMIZATIONS
CAPS Build Specs
EQUIPMENT
STANDARD
CUSTOMIZE
Roof
Pitched Roof
Standard
Doors
Lockable Door
Oversized Swing or Sliding Doors
Equipment Access Panels
Removable Lockable Access Panels
Standard
Ventilation Panels
Automated Aluminum Louvers
Air Intake Covers
Exterior
Floor
Skid Assembly
Tread Plate, Grated Spill Containment, Precast Concrete
Paint Color
Steel Grey, MAPS Blue or Pure White
Fully Customizable
Lighting
Dusk to Dawn LED
Exterior - Motion Activated Available
Custom Logo
Distributor or End User Logo
-
Unit Mobility
Lift Points / Skid Mounted
Standard
Ventilation
Thermostatically Controlled Ventilation
PLC Automated System Available
Piping
Aluminium Piping System
Carbon Steel, Stainless Steel, ProPress, Swagelok
Electrical
NEMA 3
Designed per Equipment Requirements
Filter
Filtration on the Air Inlet
Removable and Washable Filters Available
Interior
Lighting
Interior LED – Switched
Standard
Insulation
Non-Insulated
2" or 4" Foam Insulation
Outlet 120 V
120 V 10 Amp Convenience Plug
Standard
Wet Air Receiver
Vertical Only
80–400 Gallons, 150/200 PSI
Dry Air Receiver
Vertical Only
120–3,000 Gallons, 150/200 PSI
Filtration
Distributor Supplied
Water Separator, Coalescing, Particulate
Filtr.
Compressor
Supplied by Distributor
Piston, Rotary, Centrifugal
Air Treatment
Supplied by Distributor
Desiccant, Refrigerated, Nitrogen Generator
Piping Type
Aluminum
Welded, Threaded, ProPress, Swagelok
Regulation
Sized per CFM
VFD, Flow Controller, Opti-Flow
System
Drain Valves
Sized per CFM
EVD or Float Drain
Condensate Management
—
OWS, PolySep, Evaporator
Climate Control
—
Available
Add't

BUILD + COMMISSIONING
Built to Perform
Delivered Ready to Power
From in-house engineering and fabrication to delivery and field commissioning, each system is developed as a complete package. Built for efficient installation and long-term reliability, CAPS units are delivered ready for immediate connection and operation.
01
Define Specifications
-
System requirements and performance targets
-
Site conditions, climate, and exposure reviewed
-
Supports client or MAPS-led engineering
02
Engineering & Design
-
Canopy system layout and configuration
-
Equipment selection and sizing
-
Production-ready drawings developed
03
Fabrication
-
Built and assembled in controlled facility
-
Open-air canopy structure integrated with equipment
-
Pre-tested and prepared for delivery
04
Delivery
-
Transported as a complete unit
-
Positioned for site-specific requirements
-
Minimal site preparation required
05
Commissioning
-
Electrical and air connections completed
-
Startup and system checks performed
-
Rapid commissioning, often same-day